2372 Barton St East Hamilton, Ontario, L8E 2W7 📞 905-560-0061 / 1-855-416-5866
TECHNICAL SPECIFICATIONS
Saniswift -
AVAILABLE IN STORE
Sani 021
DESCRIPTION
The Saniswift drain pump is used to pump gray water away from a variety of fixtures in residential
applications. The system is able to discharge the waste up to 14 feet vertical and/or 140 feet horizontal.
PRODUCT INFO
-
Discharges the waste through either a 1”, 1-1/4” or 1-1/2” rigid pipe. A non-return valve is included on the discharge fitting assembly provided with the system.
-
Has been designed with a 1–1⁄ 2” vent connection on top of the lid. All plumbing codes require connection to a vent system. Either inlet located on top of the housing can be used for the vent or as an inlet. Please note that the vent system should be a two-way air vent as air needs to freely flow both ways. Note: The use of mechanical vents, air admittance valves or similar devices is not permitted.
-
Discharges gray water from a kitchen sink, shower, dishwasher, washing machine (indirect connection via laundry sink). The gray water will drain into the system via three 1–1⁄ 2” inlets, two low inlets (with built-in check valves) on either side of the housing and one on top of the enclosure.
Pump type:
Drain pump
Electrical:
120 V – 60 Hz / 4.5 Amps (Max)*
Motor:
0.3 HP oil-filled thermally protected motor
Capacitor rating:
30 microfarad
Operating Temperature:
140ÅãF
Power cord length:
48 inches
Noise level:
≤ 44 dBA (Lp) (measured at 3 ft.)
Discharge pipe diameter:
1”- 1–1/2”
Discharge rate at 14 ft:
18 GPM
Discharge rate at 3 ft:
24 GPM
Shut-off head:
25 ft.
Normal running time:
3-5 seconds (Short bursts)
Capacity:
2.75 gallons / 10.4 liters
Inlets:
1–1/2” (sides), 1–1⁄2” vent (top)
Method of activation:
pressure switch/ circuit board
Shower/bathtub base height:
6” min
Weight:
13 lbs / 5.9 kg
Certifying agencies:
CSA (IPC, NSPC)
Recommended accessories:
Descaler
Connections:
Sink, shower, washing machine (indirect),
dishwasher, laundry sink, etc.
* Measured using 1” discharge. Information will vary once the discharge size is increased. Consult with factory.