2372 Barton St East Hamilton, Ontario, L8E 2W7 📞 905-560-0061 / 1-855-416-5866
TECHNICAL SPECIFICATIONS
Pump type:
Grinder
Electrical:
120 V – 60 Hz / 9 Amps (Max)
Motor:
1 HP oil-filled thermally protected motor
Capacitor rating:
60 microfarad
Operating Temperature:
104ÅãF (110ÅãF Max.)
Power cord length:
49 inches
Noise level:
≤ 63 dBA (Lp) (measured at 3 ft.)
Discharge pipe diameter:
3⁄4” or 1”
Discharge rate at 25 ft:
19 GPM
Discharge rate at 3 ft:
38 GPM
Shut-off head:
38 ft.
Normal running time:
10-12 seconds
Capacity:
3.2 gallons / 12.1 liters
Inlets:
2” (side), 1–1⁄2” vent (top)
Method of activation:
Membrane/microswitch
Shower/bathtub base height:
8” min
Weight:
28 lbs / 12.7 kg
Certifying agencies:
CSA (IPC, NSPC), IAPMO (UPC)
Recommended accessories:
Descaler, Sanialarm
Connections:
Rear outlet toilet, sink, shower/bathtub, washing
20 -5/16" machine (indirect connection via laundry sink)
Saniaccess 3 -
SPECIAL ORDER
Sani 082
DESCRIPTION
The Saniaccess3 is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer
line, or even up to 150 feet away from a soil stack. It incorporates a macerating system which can handle
human waste and toilet paper in residential applications. The blade is made out of a hardened stainless steel
material which eliminates the need for any service or replacement.
PRODUCT INFO
-
Discharges the waste through a 3 ⁄4” or 1” rigid pipe. A non-return valve is included on the discharge elbow assembly provided with the system. This elbow can be rotated 360 degrees depending on the discharge installation.
-
Has been designed with a 1–1⁄2” vent connection on the top of the lid. All plumbing codes require connection to a vent system. Please note that the vent system should be a two-way air vent as air needs to freely flow both ways. Note: The use of mechanical vents, air admittance valves or similar devices is not permitted.
-
Must be connected to Saniflo’s 1.28 GPF / 4.8 LPF rear discharge toilet. These toilets come in round and elongated (ADA compliant) models. More technical information on page 6.
-
Will also discharge gray water from any sink, bath/shower or urinal. The wastewater will drain into the system via two 2” inlets with built-in check valves on either side of the housing. Note that when adding a bathtub/shower, the base should be raised up by a minimum of 6” off the floor.
-
Designed with two easy access service panels located on top of the pump. On one side of the pump you can easily access the electrical components and the level