top of page

TECHNICAL SPECIFICATIONS

Pump type:

Grinder

Electrical:

120 V – 60 Hz / 9 Amps (Max)

Motor:

1 HP oil-filled thermally protected motor

Capacitor rating:

60 microfarad

Operating Temperature:

104ÅãF (110ÅãF Max.)

Power cord length:

49 inches

Noise level:

≤ 63 dBA (Lp) (measured at 3 ft.)

Discharge pipe diameter:

3⁄4” or 1”

Discharge rate at 25 ft:

19 GPM

Discharge rate at 3 ft:

38 GPM

Shut-off head:

38 ft.

Normal running time:

10-12 seconds

Capacity:

3.2 gallons / 12.1 liters

Inlets:

2” (side), 1–1⁄2” vent (top)

Method of activation:

Membrane/microswitch

Shower/bathtub base height:

8” min

Weight:

28 lbs / 12.7 kg

Certifying agencies:

CSA (IPC, NSPC), IAPMO (UPC)

Recommended accessories:

Descaler, Sanialarm

Connections:

Rear outlet toilet, sink, shower/bathtub, washing

20 -5/16" machine (indirect connection via laundry sink)

Saniaccess 3 - 
SPECIAL ORDER

Sani 082

DESCRIPTION

The Saniaccess3 is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer

line, or even up to 150 feet away from a soil stack. It incorporates a macerating system which can handle

human waste and toilet paper in residential applications. The blade is made out of a hardened stainless steel

material which eliminates the need for any service or replacement.

PRODUCT INFO

  • Discharges the waste through a 3 ⁄4” or 1” rigid pipe. A non-return valve is included on the discharge elbow assembly provided with the system. This elbow can be rotated 360 degrees depending on the discharge installation.

  • Has been designed with a 1–1⁄2” vent connection on the top of the lid. All plumbing codes require connection to a vent system. Please note that the vent system should be a two-way air vent as air needs to freely flow both ways. Note: The use of mechanical vents, air admittance valves or similar devices is not permitted.

  • Must be connected to Saniflo’s 1.28 GPF / 4.8 LPF rear discharge toilet. These toilets come in round and elongated (ADA compliant) models. More technical information on page 6.

  • Will also discharge gray water from any sink, bath/shower or urinal. The wastewater will drain into the system via two 2” inlets with built-in check valves on either side of the housing. Note that when adding a bathtub/shower, the base should be raised up by a minimum of 6” off the floor.

  • Designed with two easy access service panels located on top of the pump. On one side of the pump you can easily access the electrical components and the level