2372 Barton St East Hamilton, Ontario, L8E 2W7 📞 905-560-0061 / 1-855-416-5866
TECHNICAL SPECIFICATIONS
Pump type:
Macerator
Electrical:
110 V – 60 Hz / 4.5 Amps (Max)
Motor:
0.5 HP oil-filled thermally protected motor
Capacitor rating:
45 microfarad
Operating Temperature:
104ÅãF (110ÅãF Max.)
Power cord length:
48 inches
Noise level:
≤ 53 dBA (Lp) (measured at 3 ft.)
Discharge pipe diameter:
3⁄4” or 1”
Discharge rate at 15 ft:
17 GPM
Discharge rate at 3 ft:
27 GPM
Shut-off head:
30 ft.
Normal running time:
Depends on toilet system
Capacity:
3.5 gallons / 13.2 liters
Inlets:
1–1/2” (sides), 1–1⁄2” vent (top)
Method of activation:
Membrane/microswitch
Shower/bathtub base height:
6” min
Weight:
17 lbs / 7.7 kg
Certifying agencies:
CSA (IPC, NSPC), IAPMO (UPC)
Recommended accessories:
Descaler, Sanialarm
Connections:
Wall hung toilet, sink, shower
Sanipack -
SPECIAL ORDER
Sani 011
DESCRIPTION
The Sanipack is a 1/2 HP pump system used to install a complete bathroom up to 15 feet below the sewer
line, or even up to 150 feet away from a soil stack. It incorporates a macerating system which can handle
human waste and toilet paper in residential applications. The blade is made out of a hardened stainless steel
material which eliminates the need for any service or replacement.
PRODUCT INFO
-
Discharges the waste through a 3⁄4” or 1” rigid pipe. A non-return valve is included on the discharge elbow assembly provided with the system. This elbow can be rotated 360 degrees depending on the discharge installation.
-
Has been designed with a 1–1 ⁄ 2 ” vent connection on the top of the lid. All plumbing codes require connection to a vent system. Please note that the vent system should be a two-way air vent as air needs to freely flow both ways. Note: The use of mechanical vents, air admittance valves or similar devices is not permitted.
-
This pump is designed to be connected to any wall-hung toilet (not supplied by Saniflo). Note that there should be a minimum 1⁄4” per foot gravity fall on the waste pipe coming from the toilet into the pump.
-
Will also discharge gray water from any sink, shower or urinal. The wastewater will drain into the system via two 1–1 ⁄ 2 ” inlets with built-in check valves on either side of the housing. Note that when adding a shower, the base should be raised up by a minimum of 6” off the floor.